Hardened Outdoor Assemblies

Hardened Drop Fiber Optic Pigtail

Close tabs
Hardened Drop Fiber Optic Pigtail

Hardened Drop Fiber Optic Pigtail

This factory preterminated flat drop pigtail is the industry standard for existing FTTx installations, it provides a quick and easy "plug and play" connection from the pedestal or handholes to the network terminals (ONTs) and can be installed in aerial, direct-buried or duct installations, reducing the cost and time of drop cable deployment simplifying installation and maintenance by reducing splicing in the distribution portion of the network.

General Characteristics

  • Custom lengths from 15 to2000 ft
  • Serial number for each pigtail
  • Male SC/ APC Hardened Connector insertion loss less than 0.40 dB
  • Return loss <-65 dB (APC)
  • UV resistant
  • Operating temperatures: -13° F to +158° F(-25° C to +70°C)
  • Storage temperature: -40° F to +158° F(-40° C to +70°C)
  • All pigtails are100% tested
  • Environmentally stable
Hardened Drop Fiber Optic Pigtail - Data Sheet
Standards
GR-326-CORE
GR-3120-CORE
GR-1209/ 1221-CORE
RoHS
IP68 / NEMA 6P
ANSI/ TIA-568-C.3
ANSI/TIA-598-C
Applications
FTTx application
Many of our fiber optic cable assemblies are highly configurable .If you don't see what you are looking for or have questions, please email us at [email protected]

Hardened Drop Fiber Optic Patch Cord

Close tabs
Hardened Drop Fiber Optic Patch Cord

Hardened Drop Fiber Optic Patch Cord

This factory preterminated flat drop patch cord is the industry standard for existing FTTx installations, it provides a quick and easy "plug and play" connection from the pedestal or handholes to the network terminals (ONTs) and can be installed in aerial, direct-buried or duct installations, reducing the cost and time of drop cable deployment simplifying installation and maintenance.

General Characteristics

  • Custom lengths from 15 to 2000 ft
  • Serial number for each patch cord
  • Male SC/ APC Hardened Connector insertion loss less than 0.40 dB
  • Return loss <-65 dB (APC)
  • UV resistant
  • Operating temperatures: -13° F to +158° F(-25° C to +70°C)
  • Storage temperature: -40° F to +158° F(-40° C to +70°C)
  • All patch cords are 100% tested
  • Environmentally stable
Hardened Drop Fiber Optic Patch Cord - Data Sheet
Standards
GR-326-CORE
GR-3120-CORE
GR-1209/ 1221-CORE
RoHS
 IP68 / NEMA 6P
 ANSI/ TIA-568-C.3
ANSI/ TIA-598-C
 Applications
FTTx application
Many of our fiber optic cable assemblies are highly configurable .If you don't see what you are looking for or have questions, please email us at [email protected]